HO Sauter Mobile Ultrasound Hardness Tester

Range: : 1 - 10HV

More Views

Description

Application: This ultrasound hardness testing device is ideally suited for mobile hardness testing, where the main emphasis is on obtaining rapid and precise results

Principle: The SAUTER HO measures using a Vickers diamond tip, which is pressed into the test piece with a defined force. After that the tip is moved into high-frequency ultrasound vibrations. The hardness is derived from the attenuation

Examples: The HO ultrasound hardness testing system is primarily used for measuring small forgings, castings, welding points, punched parts, casting tools, ball bearings and the flanks of gear wheels as well as for measuring the influence of warmth or heat

Advantages compared with Rockwell and Brinell: Less test force and therefore only microscopic, small penetrations means that the testing is less destructive

Advantages compared with Vickers: Demanding optical measuring is not required. You can therefore carry out measurements directly on-site, for example, on a permanently installed workpiece

Advantages compared with Leeb: The high requirements for the weight of the test object are no longer required, in most cases

Standards: The device fulfils these technical standards: DIN 50159-1-2008; ASTMA1038-2005; JB/T9377-2013

Mini statistics function: Display of the measuring result, the number of measurements, the maximum and minimum value as well as the average value and the standard deviation

Measurement data memory saves up to 1000 measurement groups each with 20 individual values

Calibration: The device can be adjusted to standard hardness comparison plates as well as to individual reference standards

Scope of supplies: Display unit, UCI sensor unit, transport case, software to transfer the saved data to the PC, accessories

HO Sauter Mobile Ultrasound Hardness Tester

Range: : 1 - 10HV

Sauter's HO ultrasound hardness testing device is ideally suited for mobile hardness testing, where the main emphasis is on obtaining rapid and precise results. This device measures using a Vickers diamond tip, which is pressed into the test piece with a defined force. This ultrasound hardness testing system is primarily used for measuring small forgings, castings, welding points, punched parts, casting tools, ball bearings and the flanks of gear wheels.
View additional details.

There are 4 variations of this product available:
HO Sauter Mobile Ultrasound Hardness Tester

HO 1K - Click name for details

Hardness Type
HV 1
Hardness Range
HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2
Precision
± 3 HV ± 1.5 HR ± 3 % HB

Excl. VAT: £4,500.00 Incl. VAT: £5,400.00
HO Sauter Mobile Ultrasound Hardness Tester

HO 2K - Click name for details

Hardness Type
HV 2
Hardness Range
HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2
Precision
± 3 HV ± 1.5 HR ± 3 % HB

Excl. VAT: £4,500.00 Incl. VAT: £5,400.00
HO Sauter Mobile Ultrasound Hardness Tester

HO 5K - Click name for details

Hardness Type
HV 5
Hardness Range
HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2
Precision
± 3 HV; ± 1,5 HR; ± 3 % HB

Excl. VAT: £4,500.00 Incl. VAT: £5,400.00
HO Sauter Mobile Ultrasound Hardness Tester

HO 10K - Click name for details

Hardness Type
HV 10
Hardness Range
HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2
Precision
± 3 HV ± 1.5 HR ± 3 % HB

Excl. VAT: £4,500.00 Incl. VAT: £5,400.00
Product Features

Features

Measuring ranges: HRC: 20,3–68; HRB: 41–100; HRA: 61-85,6; HV: 80–1599; HB: 76–618; Tensile strength: 255–2180 N/mm2

Precision: ± 3 HV; ± 1,5 HR; ± 3 % HB

Measuring time: adjustable from 1-5 sec.

Display units: HRC, HV, HBS, HBW, HK, HRA, HRD, HR15N, HR30N, HR45N, HS, HRF, HR15T, HR30T, HR45T, HRB.

Rechargeable battery integrated, standard, operating time up to 12 h without backlight, charging time approx. 8 h

Minimum weight of the test object: 300 g for direct measurement with the sensor (included); 100 g with support ring (optional)

Minimum thickness of the test object: 1 mm

Minimum dimensions the test surface size around: approx. 5×5 mm (recommended)

Overall dimensions W×D×H 160×83×28 mm

Permissible ambient temperature -10 °C/40 °C

Net weight approx. 0,7 kg

Key Product Specifications Chart

KEY SPECIFICATIONS

ProductHardness TypeHardness RangePrecisionMin. Sample ThicknessMaterial
HO 1K - Click name for details HV 1HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2± 3 HV ± 1.5 HR ± 3 % HB1mmMetal lacquered
HO 2K - Click name for details HV 2HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2± 3 HV ± 1.5 HR ± 3 % HB1mmMetal lacquered
HO 5K - Click name for details HV 5HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2± 3 HV; ± 1,5 HR; ± 3 % HB1mmMetal lacquered
HO 10K - Click name for details HV 10HRC: 20.3-68 HRB: 41-100 HRA: 61-85.6 HV: 80-1599 HB: 76-618 Tensile strength: 255-2180 N/mm2± 3 HV ± 1.5 HR ± 3 % HB1mmMetal lacquered